MODEL |
GNM 10 |
GNM 20 |
GNM 30 |
GNM 40 |
GNT 10 |
GNT 15 |
GNT 20 |
GNT 30 |
GNT 40 |
GNT 60 |
GNT 80 |
GNT 100 |
GNT 120 |
GNT 160 |
GNT 200 |
PHASE (IN/OUT) |
3 PHASE / 1 PHASE |
3 PHASE / 3 PHASE |
CAPACITY |
10 KVA / 8 KW |
20 KVA / 16 KW |
30 KVA / 24 KW |
40 KVA / 32 KW |
10 KVA / 8 KW |
15 KVA / 12 KW |
20 KVA / 16 KW |
30 KVA / 24 KW |
40 KVA / 32 KW |
60 KVA / 48 KW |
80 KVA / 64 KW |
100 KVA / 80 KW |
120 KVA / 96 KW |
160 KVA / 128 KW |
200 KVA / 160 KW |
INPUT |
Nominal Voltage |
3 x 380
VAC/400 VAC |
Acceptable Voltage
Range |
285 VAC ~ 475 VAC |
285 VAC ~ 485 VAC |
Frequency |
50/60 Hz ± 10 % |
INVERTER |
Nominal Voltage |
220 VAC/230 VAC/240 VAC (1Ph + N) |
3 x 380 VAC/400 VAC (3Ph + N) |
Precision |
Stationary: ±1% |
Transitory: ±5%
(load variations 100-0-100%) |
Frequency |
50/60 Hz synchronised ±1 % |
With mains absent
±0.1 Hz |
Max.
Synchronization Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic
Distortion (THDv) |
<2% (Linear Load) ; <5% (Non-linear Load) |
Dynamic Recovery
Time |
3 cycles at 90 % of the static value |
Admissible Overload |
110% for 10min; 150% for 60sec ; >160% for
200ms |
Admissible Crest
Factor |
3:1 |
Admissible Power
Factor |
0.6~1 (inductive or capacitive) |
Imbalance Output Voltage @ 100% Unbalanced Load |
<1% |
Total
Harmonic Distortion (THDv) |
High overload, short-circuit: RMS Voltage Limit |
High Crest-Factor
current: Peak Voltage Limit |
STATIC BYPASS |
Type |
Solid state |
Voltage |
220 VAC |
380 VAC/400 VAC (3Ph + N) |
Frequency |
50/60 Hz |
Activation
Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissible Overload |
150% for 1 hour; 180% for 30sec; >200% for
200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
Type |
Without interruption |
Voltage |
220VAC |
380VAC/400VAC (3Ph + N) |
Frequency |
50/60 Hz |
SYSTEM |
Overall Efficiency |
Line Mode |
≥92% |
≥93% |
≥94% |
Battery Mode |
≥92.5% |
≥93% |
≥94% |
ECO Mode
(Non-parallel models) |
Yes |
EPO Function |
Yes |
Standard |
IEC 61000-4-5 Protection surge, IEC 62040-2
EMC/EMI, IEC62040-1 Safety |
BATTERY &
CHARGER |
Battery Type and Numbers |
12VDC x 32 pcs (29~32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A; Maximum 40A; 5A@ full load |
Charging Voltage |
432 VDC (Based on 32pcs batteries) |
PHYSICAL |
Dimensions, D x W x
H (mm) |
656 x 405 x 817 |
821 x 432 x 1159 |
656 x 405 x 817 |
656 x 405 x 941 |
821 x 432 x 1159 |
975 x 554 x 1286 |
975 x 554 x 1326 |
1051 x 705 x 1646 |
Net Weight (Kgs) |
118 |
145 |
193 |
278 |
118 |
128 |
145 |
193 |
278 |
365 |
471 |
573 |
650 |
760 |
790 |
ENVIRONMENT |
Operation
Temperature |
0 - 35°C
continuous running, 40°C 8-hour running at nominal input voltage, recharging
batteries and no overload, 45°C derating to 85% with linear load |
Operation Humidity |
0~90% (non-condensing) |
Noise Level |
Less than 70dB @ 1 Meter |
MANAGEMENT |
Modbus RS-232/RS485 |
Supports Windows® 2000/2003/XP/Vista/2008/7/8/10,
Linux and MAC |
Dry Contacts |
6 outputs and 2 inputs |
Optional SNMP |
Power management from SNMP manager and web browser |